Skip to main content

Table 2 Number of readily biodegradable substances with simulation test data per compartment. The right-hand side of the table shows how many of those data points met all of the data quality criteria defined and were included in the final data set. A similar assessment of the non-readily biodegradable substances is available in Additional file 1: Table S2

From: Are ready biodegradation tests effective screens for non-persistence in all environmental compartments?

Readily biodegradable substances

Preliminary data set

Final data set (data meeting all quality criteria)

Simulation study compartment

Water

Soil

Sediment

Water

Soil

Sediment

No. of simulation studies

17

64

17

2

5

4

No. of substances meeting P criteria before temperature correction (in percent)

3 (18%)

2 (3%)

4 (24%)

0

0

0

No. of substances meeting P criteria after temperature correction (in percent)

4 (24%)

8 (13%)

7 (41%)

0

0

0