Skip to main content

Table 4 Parameters for adsorber design and operation

From: Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger

Column diameter

GCS test

GAC pilot plant

IEX

0.05 m

0.3 m

0.1 m

GAC bed depth

0.8 m

1 m

2 m

3 m

4 m

1 m

EBCT

2.4 min

8 min

16 min

24 min

32 min

2.4–6 min