Model parameters | Parameters settings |
---|---|
Inlet | Mass flow inlet, with a flow rate of 2.19 L/s |
Wall | No-slip condition and enhanced wall treatment |
Free surface | Symmetry plane |
Outlet | Pressure outlet |
Turbulent flow | k–ε RNG model |
Flow time step size | 0.1 s |
Iterations per flow time step | 20 |