Skip to main content

Table 5 Goodness-of-fit measures for the three reservoirs Eibenstock (ES), Lichtenberg (LB), and Saidenbach (SB) for the periods of model calibration (calib.) and validation (valid.), 8 years each

From: Managing climate change in drinking water reservoirs: potentials and limitations of dynamic withdrawal strategies

Reservoir

RMSE (°C)

NSE (−)

r (−)

PRE (%)

NMAE (−)

calib.

valid.

calib.

valid.

calib.

valid.

calib.

valid.

calib.

valid.

ES

1.09

1.07

0.93

0.93

0.94

0.94

−4.0

0.6

0.15

0.12

LB

1.09

1.09

0.95

0.95

0.97

0.97

−1.1

−3.4

0.14

0.13

SB

1.18

1.27

0.93

0.92

0.94

0.94

−3.4

−1.2

0.16

0.14

  1. RMSE root mean square error, NSE Nash–Sutcliffe efficiency, r Pearson correlation coefficient, PRE percentage relative error, NMAE normalized mean absolute error